DESCRIPTION:
The Autoranging EC/TDS/NaCl/Temperature Laboratory Bench Meter
MI170 measures 4 different parameters- EC, TDS, percentage of NaCI and Temperature in a variety of ranges.
The auto-ranging feature for EC and TDS measurements automatically sets the resolution suitable to the tested
sample. All measurements can be temperature compensated at 20 or 25oC and the compensation
coefficient is selectable by the user.
The automatic temperature compensation can also be disabled for measuring the actual conductivity valve.
The stability indicator on the LCD ensures accuracy.
Conductivity readings are performed with the 4-ring probe supplied with the meter. The GLP feature allows
users to store and recall data on system status. PC compatible through an RS232 or USB port.
Some of the MI170 features include:
SPECIFICATIONS:
| Range |
0.00 to 29.99 µS/cm; 30.0 299.9 µS/cm; 3.00 to 29.99 mS/cm; 30.0 to 200.0 mS/cm; up to 500.0 mS/cm actual conductivity (uncompensated EC*) 0.00 to 14.99 mg/L (ppm); 15.0 to 149.9 mg/L (ppm); 150 to 1499 mg/L (ppm); 1.5 to 14.99 g/l (ppt); 15.0 to 100.0 g/l (ppt); up to 400.0 g/l actual TDS (with .080 factor) 0.0 to 400.0% -20.0 to 120.0°C / -4.0 to 248.0°F |
| Resolution |
0.01 µS/cm; 0.1 µS/cm; 1.0 µS/cm; 0.01 mS/cm; 0.1 mS/cm 0.01 mg/L; 0.1 mg/L; 1.0 mg/L; 0.01 g/l; 0.1 g/l 0.1% 0.1°C / 0.1°F |
| Accuracy |
± 1% of reading ± (0.05 µS/cm or 1 digit) ± 1% of reading ± (0.03 mg/L or 1 digit) ± 1% of reading ± 0.4% / ± 08°F |
| Calibration | 1 point slope calibration with 6 memorized solutions available (84.0 µS, 1413 µS, 5.00 mS/cm, 12.88 mS/cm 80.0 mS/cm, 111.8 mS/cm) 1 point, with MA9066 calibration solution |
| Temperature Compensation | automatic or manual , from -20.0 to 120.0°C / -40. to 248.0°F |
| Temperature Coefficient | Selectable from 0.00 to 6.00% / °C (EC and TDS only) |
| Probe | MA814D/1 (4 ring electrode with temperature probe included) |
| TDS Factor | 0.40 to 0.80 (default value is 0.50) |
| Log on demand (samples) | 50 on each range (EC, TDS, NaCL) |
| GLP | Last EC, NaCL calibration data |
| PC Interface | RS232 / USB Opto-isolated |
| Enviornment | 0 to 50°C / 32 to 122°F; max RH 95% |
| Power supply | 12 VDC power adapter |
| Dimensions | 230 x 160 x 95mm |
HOW TO ORDER:
MI170: Autoranging EC/TDS/NaCl/Temperature Laboratory Bench Meter....$475.00
ACCESSORIES:
MA813D/1: EC/TDS/NaCI/Temperature Probe with 1m cable.... $Check Pricing
MA9060: 12880 uS/cm Calibration Solution, 220mL Bottle.... $Check Pricing
MA9061: 1413 uS/cm Calibration Solution, 220mL Bottle.... $Check Pricing
MI5200: Application Software.... $25.00